FOCSUN has the world's largest direct refrigeration (direct cooling) block ice machine production and research and development base. Up to now, we have provided high quality products and one-stop service to many famous customers all over the world.
FOCUSUN direct refrigeration block ice machine adopts modular design. The large capacity direct refrigeration block ice machine is divided into machine modular, evaporator modular and outside cooling modular, convenient to transport and install.
Machine modular: includes compressor, liquid reservoir, water cooling condenser, cooling pipe, valve, control box and so on.
Outside cooling modular: water cooling tower, air cooling condenser, evaporative condenser. They are usually placed outside.
Evaporator modular: evaporator modules are divided into one or several sizes according to the size of evaporator.
All modules meet the requirements of container transportation.
Large capacity direct refrigeration block ice machine adopts screw compressor, with excellent energy saving data. FOCUSN engineers spend years researching and exploring to provide customers with 63KW/ tons of ice making machine which has been called "energy saving king".
Model Capacity Refrigerant Electricity consumption Installment power Operating weight Dimension
Model | Capacity | Refrigerant | Electricity consumption | Installment power | Operating weight | Dimension |
---|---|---|---|---|---|---|
-- | Ton/D | -- | Kw | Kw | Kg | mm |
FIB-50D | 5.0 | R22/R404A | 20.900 | 25.0 | Unit | L1400×W1000×H1250 |
Evaporator | L4800×W1000×H2250 | |||||
Cooling tower | Ф1380×H2170 | |||||
FIB-100D | 10.0 | R22/R404A | 33.980 | 50.0 | Unit:1680 | L1800×W1000×H1450 |
Evaporator: 2860×2 |
L4800×W1000×H2250 | |||||
Cooling tower: 670 |
Ф2000×H2410 | |||||
FIB-150D | 15.0 | R22/R404A | 59.150 | 75.0 | Unit:2160 | L2000×W1200×H1600 |
Evaporator: 2860×3 |
L4800×W1000×H2250 | |||||
Cooling tower:1120 | Ф2175×H2565 | |||||
FIB-200D | 20.0 | R22/R404A | 85.550 | 105.0 | Unit:2896 | L2400×W1600×H1800 |
Evaporator: 2860×4 |
L4800×W1000×H2250 | |||||
Cooling tower:1300 | Ф2650×H2645 | |||||
FIB-250D | 25.0 | R22/R404A | 94.050 | 120.0 | Unit:3260 | L3200×W1800×H2200 |
Evaporator: 2860×5 |
L4800×W1000×H2250 | |||||
Cooling tower: 1630 |
Ф3050×H2780 | |||||
FIB-300D | 30.0 | R22/R404A | 113.550 | 150.0 | Unit:3500 | L3000×W2000×H2200 |
Evaporator: 2860×6 |
L4800×W1000×H2250 | |||||
Cooling tower: 2730 |
Ф3300×H2785 | |||||
Standard condition: Dry ball temperature is 33 ℃ and water inlet temperature is 20℃. |
|
|
|
|
||||||||
|
|