| Item | Unit | Parameter | ||||
|---|---|---|---|---|---|---|
| Power supply | Voltage/Phase/Frequency | 380V/3P/50Hz | ||||
| Refrigerant | R404A | |||||
| Capacity | kg/24h | 60000 | ||||
| Cooling Way | Water Cooling | |||||
| Temperature | Ambient Temperature | ℃ | 35 | |||
| Water Temperature | ℃ | 20 | ||||
| Compressor | Manufacturer | Bitzer/Carrier | ||||
| Refrigeration Power | kw | 342 | ||||
| Operating Power | kw | 190 | ||||
| Compressor COP/EER | kw/kw | 1.92 | ||||
| Horse Power | hp | 125×2 | ||||
| Operating power | Total running power | kw | 204.9 | |||
| Installation Power | kw | 230 | ||||
| Power of Reducer | kw | 4.2 | ||||
| Power of Cold Water Pump | kw | 2.75 | ||||
| Cooling Water Pump | kw | 15 | ||||
| Fan of Cooling Tower | kw | 4.2 | ||||
| Dimension | Size of Ice Maker | L×W×H(mm) | 12192×2438×2895 | |||
| Size of Cooling Tower | L×W×H(mm) | ¢2650×2645 | ||||
| Size of Cooling Water Pipes | 5" | |||||
| Size of Feeding Pipe | 1" | |||||
| Size of Water Feeding Pipes of Cooling Tower | 1" | |||||
| Size of Ice Outlet | mm | ¢2000 | ||||
| Weight | Operating Weight of Flake Ice Maker | kg | 9200 | |||
| Operating Weight of Cooling Tower | kg | 1300 | ||||
| Water Supply Pressure Requirement | bar | 1~6 | ||||