| Subject | Unit | Technical parameter | |
|---|---|---|---|
| Power supply | Voltage/Phase/Frequency | 380V/3P/50Hz | |
| Refrigerant | R22 or R404A | ||
| Capacity | Kg/day | 20000 | |
| Cooling way | Water cooling | ||
| Temperature | Ambient temperature | ℃ | 35 | 
| Waterinlet temperature | ℃ | 20 | |
| Compressor | Manufacturer | Bitzer | |
| Refrigeration capacity | Kw | 108 | |
| Total running power | Kw | 53.16 | |
| Compressor COP/EER | Kw/kw | 2.03 | |
| Horse power | Hp | 30×3sets | |
| Operating power | Total running power | Kw | 60.41 | 
| Installment power | Kw | 80 | |
| Operating power of reducer | Kw | 1.5 | |
| Operating power of cold water pump | Kw | 0.55 | |
| Cooling water pump | Kw | 3.7 | |
| Fan of cooling tower | Kw | 1.5 | |
| Dimension | Size of ice maker | (L×W×H)(mm) | 4200×2000×2914 | 
| Size of cooling tower | (O.D.×H)(mm) | Φ2175×2565 | |
| Size of water feeding pipes of cooling tower | 3/4" | ||
| Size of cooling water pipes | 3" | ||
| Size of water feeding pipe | 3/4" | ||
| Size of ice outlet | mm | Φ1425 | |
| Weight of unit | Operating weight of flake ice maker | Kg | 3600 | 
| Operating weight of cooling tower | Kg | 1120 | |
| Water supply pressure requirement | Bar | 1.5 | |
| 
 | 
 | 
 | 
 | ||||||||
| 
 | 
 | 
 |