| Subject | Unit | Technical parameter | |
|---|---|---|---|
| Power supply | Voltage/Phase/Frequency | 380V/3P/50Hz | |
| Refrigerant | R22 or R404A | ||
| Capacity | Kg/day | 3000 | |
| Cooling way | Water cooling | ||
| Temperature | Ambient temperature | ℃ | 35 | 
| Waterinlet temperature | ℃ | 20 | |
| Compressor | Manufacturer | Bitzer | |
| Refrigeration capacity | Kw | 16.8 | |
| Total running power | Kw | 7.96 | |
| Compressor COP/EER | Kw/kw | 2.11 | |
| Horse power | Hp | 12 | |
| Operating power | Total running power | Kw | 9.29 | 
| Installment power | Kw | 11 | |
| Operating power of reducer | Kw | 0.37 | |
| Operating power of cold water pump | Kw | 0.03 | |
| Cooling water pump | Kw | 0.75 | |
| Fan of cooling tower | Kw | 0.18 | |
| Dimension | Size of ice maker | (L×W×H)(mm) | 1700×900×1200 | 
| Size of cooling tower | (O.D.×H)(mm) | φ1170×1940 | |
| Size of water feeding pipes of cooling tower | 1/2" | ||
| Size of cooling water pipes | 2" | ||
| Size of water feeding pipe | 3/4" | ||
| Size of ice outlet | mm | Φ512 | |
| Weight of unit | Operating weight of flake ice maker | Kg | 950 | 
| Operating weight of cooling tower | Kg | 260 | |
| Water supply pressure requirement | Bar | 1.5 | |
| 
 | 
 | 
 | 
 | ||||||||
| 
 | 
 | 
 |