| 01 guiding rail, 02 water feeder, 03 water feeding gadget, 04 can dump, 05 crane, 06 thaw tank, 07 brine tank, 08 ice bucket, 09 evaporative coils, 10 agitator, 11 refrigeration unit, 12 electric control box |
As shown above, first fully feed the ice bucket with water, press the button and start the refrigeration system. The agitator makes the water flow cyclically which will have a heat transfer with the refrigerant inside the Ti evaporative coils and then the temperature is lowered. Then the low temperature brine water has a heat transfer with the water inside the ice bucket which will be lowered to 0℃ below. After a certain ice making time, the water in the ice bucket all becomes ice when the ice thawing system is beginning to run. The crane will hoist a row of buckets down into the ice thaw tank full of running warm water. So the bucket temperature will be rising when the ice surface thaws and gets separated from ice bucket. Then ice buckets will be hoisted to the ice can dump. Fix buckets and then rotate dump upside down and ice is dropped down. Put up the buckets and refill water to a certain level using water feeding gadget, then the crane will hoist the buckets back to the brine water tank and hoist another row of ice buckets in the brine water tank. Thaw ice, drop ice and add water cyclically.
| Brine refrigeration block ice machine technical parameter | ||||||
| Model | Capacity | Refrigerant | Electricity consumption | Installment power | Operating weight | Dimension |
|---|---|---|---|---|---|---|
| -- | Ton/D | -- | Kw | Kw | Kg | mm |
| FIB-50B | 5 | R22/R404A | 21.14 | 25 | Unit | L1400×W1000×H1250 |
| Evaporator | L4800×W1000×H2250 | |||||
| Cooling tower | Ф1380×H2170 | |||||
| FIB-100B | 10 | R22/R404A | 40.69 | 50 | Unit:1680 | L1800×W1000×H1450 |
| Evaporator: 2860×2 |
L4800×W1000×H2250 | |||||
| Cooling tower: 670 |
Ф2000×H2410 | |||||
| FIB-150B | 15 | R22/R404A | 60.60 | 75 | Unit:2160 | L2000×W1200×H1600 |
| Evaporator: 2860×3 |
L4800×W1000×H2250 | |||||
| Cooling tower: 1120 |
Ф2175×H2565 | |||||
| FIB-200B | 20 | R22/R404A | 88.50 | 105 | Unit:2896 | L2400×W1600×H1800 |
| Evaporator: 2860×4 |
L4800×W1000×H2250 | |||||
| Cooling tower: 1300 |
Ф2650×H2645 | |||||
| FIB-250B | 25 | R22/R404A | 98.80 | 120 | Unit:3260 | L3200×W1800×H2200 |
| Evaporator: 2860×5 |
L4800×W1000×H2250 | |||||
| Cooling tower: 1630 |
Ф3050×H2780 | |||||
| FIB-300B | 30 | R22/R404A | 120.30 | 150 | Unit:3500 | L3000×W2000×H2200 |
| Evaporator: 2860×6 |
L4800×W1000×H2250 | |||||
| Cooling tower: 2730 |
Ф3300×H2785 | |||||
| Standard condition: Dry ball temperature is 33 ℃ and water inlet temperature is 20℃. | ||||||
|
|
|
|
||||||||
|
|